30 Years of serving the Industrial Controls market --- Design, manufacturing and Sourcing of all your control requirements |
|
CP696 6 decade digital batch counter
Mode of Operation: This counter is programmed using the panel push switches to set the batch size and a 4 way switch at the rear to set the modes. Single shot Mode - Up count: Pulses are counted from zero until the batch size is reached then the relay is energised. The count will continue if more pulses are applied to the input but the relay remains energised until the counter is reset. Single shot Mode - Down count: The count is preset to the batch size and counts down to zero then the relay is energised. The count will remain at zero and the relay remains energised until the counter is reset. Cycle Mode - Up count: Pulses are counted from zero until the batch size is reached then the relay is energised and the counter is reset and continues to count. The relay remains energised for a period that can be set between 0.1 and 5 seconds. Cycle Mode - Down count: The count is preset to the batch size and counts down to zero then the relay is energised and the counter is reset to the preset value and continues to count. The relay remains energised for a period that can be set between 0.1 and 5 seconds. Prescaler Option {order code PS} [Click here for details] BCD output Option {order code BCD} [Click here for details] RS232/485 Output Option {order code RS232 or RS485} [Click here for details] Specification
|
|
Send mail to info@abtekcontrols.com with